CadnaB Building
The “CadnaB Building” object is a special object that is used for data exchange between CadnaA and CadnaB. The object acts both as a source and as an obstacle with the following properties:
- After establishing a link to a CadnaB project, the results calculated in CadnaA can be used for calculation of the indoor level in CadnaB.
- Furthermore, the “CadnaB Building” itself can act as a sound-emitting building radiating into its surroundings in CadnaA. This requires that calculated CadnaR project within the referenced CadnaB project.
- In both of these situations, the “CadnaB Building” also acts as an obstacle using the geometry specified in CadnaB and taking into account the building‘s height specified in CadnaB based on the storey heights.
Limitations
Roof areas of buildings are - for the time being - not part of the transmission calculation, i.e. neither sources for building radiation, nor facade points are created at those surfaces.
Procedure
The procedure consists of the following main points:
- input of the building‘s geometry in CadnaB (one project per building)
- importing this geometry into CadnaA by assigning a CadnaB project file via the “CadnaB Building” object
- calculation of the facade levels or building radiation using CadnaA.
- export of the calculation results from CadnaA to CadnaB.
Dialog options

CadnaA Building dialog
Name, Memo-Window, ID, ObjectTree
see Dialog Options Name, ID, INFO, ObjectTree, Master in the manual "Introduction to CadnaA"
File
Select via the file selector symbol
the CadnaB file to be used for data exchange.
Reflection
see Chapter 3 - Obstacles, Reflection Properties
Consider that reflections at the surface of the “CadnaB Building” object are only generated provided at least the first reflection order is set in the calculation configuration, “Reflection” tab (see Reflection Tab).
Land Use
see Receiver, Specifying Limiting Values
Note
NOTE: This feature is not used for the time being.
Operating Time
see Common Input Data, Specifying Limiting Values
This option is only relevant when the CadnaB Building acts as a radiating source in CadnaA.
Geometry
The geometry of the CadnaB building is based on the modeling in CadnaB. The position of the CadnaB-Building in CadnaA is then defined via x/y center coordinate and a rotation angle (if required).
Buttons
Directivity
see Receiver, Directivity
Interop
opens a table with the coordinates x/y/z/ground and calculation results (A-weighted sum level and - if any - third octave band spectrum) at all facade points. If the CadnaB-Building acts as a radiating source, the sound power levels in front of the facade transferred from CadnaB is shown in the column „Lw“.
Sync A->B
Clicking this button synchronizes the results of the calculation in CadnaA with CadnaB (export).
Sync B->A
Clicking this button synchronizes the data from the CadnaB project file with the current CadnaB building object in CadnaA (import).
Note
In both cases („Sync A->B“ and „Sync B->A“) the CadnaB project file/s does/do not have to be opened in CadnaB.
Regarding settings for automatic synchronization, see Options for CadnaB Interop.