Skip to content

ObjAtt

returns the parameter values or option settings for specific tasks of CadnaA (e.g. Configuration of Calculations)

Syntax #(Keyword, Parameter 1, Parameter 2, Parameter 3)
Keyword ObjAtt
Parameter 1 CALCCONF, GLK_OPT, OBJ_SCAN
Parameter 2 see following tables
Parameter 3 number of decimals (with numerical values)

Configuration of Calculations

„Standards“ tab

Parameter 2 Explanation Type
NORM_IND standard for „Industry“ (VDI, ISO, ISO24 O28, DIN, NORD, N2000, N_VIND, BS5228, HARM, CONC, S03NI, CNS_IN) text
NORM_ROAD standard for „Road“ (RLS, RVS, STL, DIN, NORD, NMPB, NMPB08, CRTN, TNM, LIBER, SONR, SONR18, CNS_RD) text
NORM_RAIL standard for „Railway“ (S03, S5011, DIN, SEMI, CRN, SRM2, S03N, NFER, NFER08, RR_USA, CNS_RL) text
NORM_ACFT standard for „Aircraft“ (AZB, AZB08, ECAC, DIN, OAL24, INM, ECAC3, CNS_F) text

„General“ tab

Parameter 2 Explanation Type
MAXERROR Maximum Error (dB) value
SEARCHRAD Maximum Search Radius (m) value
MINDISTSR Minimum Distance Source to Rcvr (m) value
GRD_XTRAP_B Extrapolate Grid 'under' Buildings On/Off 1/0
FAST_SCREEN Fast Screening On/Off 1/0
KSIGMA_PROP Propagation Coefficient Uncertainty (expression) text
RASTER_INT Grid Interpolation On/Off 1/0
RASINT_CRN Max. Diff. Corners (dB) value
RASINT_MID Max. Diff. Center (dB) value
ANGLESCAN Angle Scan Method On/Off 1/0
ANGLESEGS Number of Angle Segments value
REFL_DEPTH Reflection Depth value
MITHRACOMP Mithra Compatibility On/Off 1/0

„Partition“ tab

Parameter 2 Explanation Type
RASTERFACT Raster Factor (-) value
LMAX Max. Length of Section (m) value
LMIN Min. Length of Section (m) value
LMINP Min. Length of Section (%) value
PROJ_LQ Projection of Line Sources On/Off 1/0
PROJ_FQ Projection of Area Sources On/Off 1/0
PROJ_DTM Projection at Terrain Model On/Off 1/0
PROJ_DMAX Max Dist. Source-Receiver (m) value
PROJ_RAD_S Search Radius Source (m) value
PROJ_RAD_R Search Radius Receiver (m) value
PROJ_ULMIN Min. Lengths are considered by projection On/Off 1/0
PROJ_RBLRM Projection accord. to RBLärm-92 procedure 1 On/Off 1/0

„Reference Time“ tab

Parameter 2 Explanation Type
TIME_DEN string of 24 letters DEN, not assigned hours represented by the underscore „_“ text
TIME_DEN00 to TIME_DEN23 Allocation DEN (single letter), for hours 0 to 23 D, E or N
TIME_PEN_D Daytime Penalty (dB) value
TIME_PEN_E Evening/Recr. Time Penalty (dB) value
TIME_PEN_N Night-time Penalty (dB) value
TIME_SBEZ Special Reference Time for Industry On/Off 1/0
ZURU_USED „Recr. Time Penalty only for“ 1/0
ZURU_xx xx = short name of the landuse, e.g. WA, MI.
0: without penalty
1: with penalty
empty: landuse not available
value

„Evaluation Parameters“ tab

Parameter 2 Explanation Type
EVP1_TYPE to
EVP4_TYPE
list box "Type" (e.g. Ld, Le, Ln, Lden...),
toggling to „=f(x)“ by using EVPx_TYPE==f(x)
(alternatively =func or =expr)
text
EVP1_NAME to
EVP4_NAME
box "Name" text
EVP1_UNIT to
EVP4_UNIT
box "Unit" text
EVP1_EXPR to
EVP4_EXPR
box "Expression" expression

„DTM“ tab

Parameter 2 Explanation Type
DTM_DEFGND Standard Height (m) value
DTM_TYPE Model Type of Terrain [1: Search Contour Lines (Average), 2: Search Contour Lines (Local Inclined Plane), 3: Triangulation] value
DTM_EXPEDGE Explicit Edges Only On/Off 1/0
DTM_OBJGND Objects with ''Ground at every point" influence DTM On/Off 1/0
DTM_SRC_HR0 Lift 'Sources under Ground' to Ground-Niveau On/Off 1/0
DTM_FQ_GFOL Area sources with constant relative height follow terrain On/Off 1/0

„Ground Absorption“ tab

Parameter 2 Explanation Type
BABS Default Ground Absorption G value
BABSGRID Use map of ground absorption Yes/No 1/0
BABSGRIDAUT Use map of ground absorption Auto Yes/No 1/0
BABSGRID_D map of ground absorption, resolution (m):
relevant only if BABSGRID=1 or BABSGRIDAUT=1
value
BABS_ROAD_0 Roads / Parking Lots are reflecting (G==0) On/Off 1/0
BABS_BLDG_0 Buildings are reflecting (G==0) On/Off 1/0
BABS_RAIL_1 Railways are absorbing (G ==1) On/Off 1/0

„Reflection“ tab

Parameter 2 Explanation Type
REFLORDER max. Order of Reflection (1-20) value
REFL_RAD_S Search Radius Source (m) value
REFL_RAD_R Search Radius Receiver (m) value
REFL_DMAX Max. Distance Source - Receiver (m) value
REFL_DMAXI as before, Interpolate from (m) value
REFL_RMIN Min. Distance Receiver - Reflector (m) value
REFL_RMINI as before, Interpolate to (m) value
REFL_SMIN Min. Distance Source - Reflector (m) value

„Industry“ tab

Parameter 2 Explanation Type
LAT_DIFFRAC method Lateral Diffraction 0..2 value
LATDIF_DMAX if Distance smaller (m) value
SCREEN_AGR method Screening & Ground Attenuation 0..2 value
SCREEN_LIM method barrier attenuation limit 0..3 value
NO_NEG_AGRS No subtraction of negative Ground Attenuation On/Off 1/0
NO_NEG_PATH No negative path difference On/Off 1/0
OBS_AREA_NS Obstacles within Area Sources do not shield On/Off 1/0
OBS_AREA_NR Obstacles within Area Src do not reflect 1/0
SRC_BLDG_NS sources in Building/Cylinder do not shield On/Off 1/0
SCREEN_C1 Barrier Coefficient C1 (dB) value
SCREEN_C2 Barrier Coefficient C2 (dB) value
SCREEN_C3 Barrier Coefficient C3 (dB) value
O28_GUMMI ÖAL28: Screening with ''Rubber Band'' On/Off 1/0
O28_DLS_UNB ÖAL28: DeltaLS without Limit On/Off 1/0
BS52_LS_D6 BS5228: Line sources are haul roads (F.2.5) On/Off 1/0
BS52_DIA_D3 BS5228: Use diagram F.3 for screening of non-spectral sources On/Off 1/0
HARM_OCT_3 Harmonoise: Calculation in 1/3-Octave Bands On/Off 1/0
AGR_TYPE method Ground Attenuation
0 = none
1 = not spectral
2 = spectral, spectral sources only
3 = spectral, all sources
5 = -3 dB
value
CNS_ICNTID or CNS_ICNTRY CNOSSOS: Calculation acc. to:
4: 2021/1226 EU
6: 2015/996 EU
value
LAT_DIF_CNS CNOSSOS: lateral diffraction 0 = none, 1 = Point Sources 0/1
HJIN_V2021 Version of HJ 2.4:
0 = 2009
1 = 2021
value
HJIN_2D_HM Use 2D-distance for calculation of hm (A.20) 1/0
HJIN_AGRBAR 0 = Aground not considered in case of single and multiple diffraction
1 = Aground not considered in case of multiple diffraction
2 = Use maximum of Aground and Abar
value
ISO_APP_D3 Point sources are wind turbines: Checkbox D.3 0/1
ISO_APP_D3IOA Point sources are wind turbines: Checkbox IoA (2dB) 0/1
ISO_APP_D5 Point sources are wind turbines: Checkbox D.5 0/1
ISO_APP_D5IOA Point sources are wind turbines: Checkbox IoA (hs - hr) 0/1

„Meteorology“ tab

TEMP Temperature (°C) value
REL_HUMID relative Humidity (%) value
STDIR_VWIND Point Source: wind speed for directivity „Chimney“ VDI 3733 (1996) (m/s) value
CMET_METH method Cmet 0..5 value
CMET_C0D/E/N Cmet, C0 constant, Day/Evening/Night (dB) value
MET_STABCID/E/N Stability Class, Integer 1-5 od. 1-7, Day/Evening/Night value
MET_STABCD/E/N Stability Class S1..S5 or A..G, Day/Evening/Night text
MET_VWINDD/E/N wind speed (m/s), Day/Evening/Night value
MET_DWINDD/E/N wind direction in degrees (°), Day/Evening/Night value
MET_SWINDD/E/N Nord 2000: Standard Deviation Wind Speed (m/s), Day/Evening/Night value
MET_TEMPGRD/E/N Nord 2000: Temperature Gradient (°/m), Day/Evening/Night value
MET_WINDTUD/E/N Nord 2000: Turbulence Parameter for wind CV2 (m4/3/s2), Day/Evening/Night value
MET_TEMPTUD/E/N Nord 2000: Turbulence Parameter for Temperature CT2 (K/s2), Day/Evening/Night value
MET_TEMPFLD/E/N Nord 2000: Standard Deviation of Fluctuations of the Temperature Gradient σdt/dz (°C/m), Day/Evening/Night value
MET_INT_CAT CONCAWE: Interpolate meteorological Category On/Off 1/0
MET_H_WIND Nord 2000: Height of Wind (m) value
MET_ROUGHL Nord 2000: Roughness Length (m) value
MET_CNS_PD/E/N CNOSSOS: percentage favorable for D/E/N value
MET_CNS_PDV/EV/NV CNOSSOS: returns 1, if MET_CNS_PD/E/N valid, otherwise 0 - read only 1/0
MET_CNS_NAM CNOSSOS: Meteorology designation text
MET_NTH_INP Direction of north:
0 = Get from first North Arrow Symbol
1 = Angle
0/1
MET_NTH_ANG Direction of north if MET_NTH_INP = 1 value

„Road“ tab

Parameter 2ExplanationType
FLG_NAT_THRNordic Prediction Method: Threshold for NATs (dB)value
ROAD_STRICTStrictly according to ... On/Off1/0
ROAD_1_REFLCalc exactly one Reflection Order On/Off1/0
ROAD_LATDIFNo Lateral Diffraction On/Off1/0
ROAD_BUILTANo Housing Attenuation On/Off1/0
ROAD_FOLIAGNo Foliage Attenuation On/Off1/0
ROAD_2LANESCalc outer Lanes separately On/Off1/0
ROAD_CMETNo Meteorology (Cmet see Industry) On/Off1/0
RLS_VBUSRLS90: Calculation acc. To VBUS On/Off1/0
RVS_QUHARTRVS: Source Region is always reflecting On/Off1/0
RVS_DOPSC25RVS: Double screening limited to 25 dB On/Off1/0
STR_PRP_RLSSTL86: Calc propagation acc. to RLS-90 On/Off1/0
ROAD_MAXLEVNordic Prediction Method: Calc maximum Pass-By-Level On/Off1/0
ROAD_MX_DOVNordic Prediction Method + CNOSSOS: toggles options LAFmaxX% (=0) or LAFmaxNth (=1)1/0
ROAD_MAXPRCNordic Prediction Method + CNOSSOS: X in LAFmaxX% (default value: 5%)value
ROAD_MAXVEHNordic Prediction Method + CNOSSOS: N in LAFmaxNth (default value: 5)value
ROAD_TSAMPLNordic Prediction Method + CNOSSOS: Sampling Interval (s)value
ROAD_REFPLANordic Prediction Method: Calc planes of reflection On/Off1/0
ROAD_RPDEVINordic Prediction Method: Reflection Plane: Max. Deviation (m)value
NMPB_EMINMPB: Type Emission Calculation 0..2value
ROAD_YEARNMPB08: Year of Calculationvalue
NMPB_ATALUS NMPB08: Calc Atalus On/Off 1/0
NMPB_USE_CH NMPB08: Use Ch in the calculation of Abar On/Off 1/0
NMPB_REFDLL NMPB08: Use reference DLL On/Off 1/0
ROAD_DENHRS Use Non-Standard Reference Time D/E/N On/Off 1/0
CRTN_LOWTRA CRTN: Low-Traffic-Correction On/Off 1/0
ANGL_REFCOR CRTN: Reflection via Correction On/Off 1/0
CRTN_DMRB CRTN: Calc acc. to DMRB On/Off 1/0
CRTN_SUBSRC CRTN: 3 sub-sources heavy vehicles On/Off 1/0
ROAD_1HEIGH All emissions at a single height On/Off 1/0
TNM_ADIVR3D TNM: Use 3D-distance On/Off 1/0
TNM_FRESNEL TNM: Correct Fresnel bug On/Off 1/0
NORD_THICKS Nordic Prediction Method: Use Correction for Thick Screens DLts On/Off 1/0
CNS_RD_TEMP CNOSSOS: Use Temperature from Industry-Tab On/Off 1/0
CRTN_LEQ On: calculates Leq acc. to TRL Study
Off: calculates L10
1/0
CRTN_LEQ3DB On: if (CRTN_LEQ On) calcs Leq=L10-3 dB
Off: see CRTN_LEQ
1/0
STL_PROPRLS STL86 (CH): Calc propagation according to RLS90 1/0
STL_NEGSCR STL86 (CH): Calculation of negative Screening according to ISO 9613 (1996) 1/0
CNS_ICNTRRD CNOSSOS: calculation acc. to:
4: 2021/1226 EU
5: 2021/1226 DE (BUB 2021)
6: 2015/996 EU
7: 2015/996 DE (BUB 2018)
8: 2015/996 AT (RVS 2019)
9: 2021/1226 AT (RVS 04.02.11 2021)
value
MET_CNS_PD/E/N CNOSSOS: percentage favorable for D/E/N value
MET_CNS_PDV/EV/NV CNOSSOS: returns 1, if MET_CNS_PD/E/N valid, otherwise 0 - read only 1/0
MET_CNS_NAM CNOSSOS: Meteorology designation text
CNS_TSTUD CNOSSOS: studded tires, Period Ts (mon) value 1..12
CNS_QSTUD CNOSSOS: studded tires, percentage Qstud, ratio (%) value
CNS_VEHCLS Vehicle class (ID of library object) Text
CNS_VMAX_XX CNOSSOS-EU: Max speed for each vehicle class (XX = 1, 2, 3, 4A, 4B oder 5) value
HJRD_V2021 Version of HJ 2.4:
0 = 2009
1 = 2021
value
HJRD_AGRSPC Aground spectral (according to GB/T 17247.2) 1/0
HJRD_2D_HM Use 2D-distance for calculation of hm (A.20) 1/0
HJRD_AGRBAR 0 = Aground not considered in case of single and multiple diffraction
1 = Aground not considered in case of multiple diffraction
2 = Use maximum of Aground and Abar
value
SONR_TEMP sonRoad18: Temperature for rolling noise value
SONR_VERS sonRoad18: Calculation acc. to:
0: 2018
1: 2021
2: 2024
value

„Railway“ tab

Parameter 2 Explanation Type
RAIL_STRICT Strictly according to ... On/Off 1/0
RAIL_1_REFL Calc exactly one Reflection Order On/Off 1/0
RAIL_LATDIF No Lateral Diffraction On/Off 1/0
RAIL_BUILTA No Housing Attenuation On/Off 1/0
RAIL_CMET No Meteorology On/Off 1/0
S03_VBUSCH Schall03: Calculation acc. To VBUSch On/Off 1/0
RAIL_CORREC Railway Correction (dB) value
RAIL_DENHRS Use Non-Standard Reference Time D/E/N On/Off 1/0
O305011_ISO ON 305011 with propagation acc. to ISO (1996) On/Off 1/0
S5011_HQ050 Source Height = 0.5 m On/Off 1/0
RAIL_MAXLEV Nordic Prediction Method: Calc maximum Pass-By-Level On/Off 1/0
RAIL_TSAMPL Nordic Prediction Method: Sampling Interval (s) value
RAIL_LMAX_F option „LmaxF“ On/Off (instead of LmaxM) 1/0
RAIL_MAX_XP Nordic Prediction Method: Extrapolate trains to 1/2 length On/Off 1/0
RAIL_1HEIGH All emissions at a single height above railhead On/Off 1/0
RAIL_ISOAIR SRMII: Air Absorption acc. to ISO 9613-1 On/Off 1/0
RAIL_ISOMET SRMII: Meteorological Correction Cmet acc. to ISO 9613-2 (1996) On/Off 1/0
NMPB_ATALUS NMPB08: Calc Atalus On/Off 1/0
NMPB_USE_CH NMPB08: Use Ch in the calculation of Abar On/Off 1/0
NMPB_REFDLL NMPB08: Use reference DLL On/Off 1/0
NMPB_SCRBDY NMPB08 / CNOSSOS: Number of Train-Barrier-Interactions value
S03N_WATER0 Schall03 (2014): Ground with G=0
represents water On/Off
1/0
S03N_3REFL Schall03 (2014): Calc exactly three Orders of Reflection On/Off 1/0
S03N_SEITB Schall03 (2014): No Lateral Diffraction On/Off 1/0
SEMI_NEGSCR Semibel (CH): Calculation of negative Screening according to ISO 9613 (1996) 1/0
CNS_ICNTRRL CNOSSOS: calculation acc. to:
3: 2015/996 FR (SNCF 2021)
4: 2021/1226 EU
5: 2021/1226 DE (BUB 2021)
6: 2015/996 EU
7: 2015/996 DE (BUB 2018)
8: 2015/996 AT (RVE 2019)
9: 2021/1226 AT (RVE 2021)
10: 2021/1226 BE
11: 2021/1226 FR (SNCF 2022)
value
MET_CNS_PD/E/N CNOSSOS: percentage favorable for D/E/N value
MET_CNS_PDV/EV/NV CNOSSOS: returns 1, if MET_CNS_PD/E/N valid, otherwise 0 - read only 1/0
MET_CNS_NAM CNOSSOS: Meteorology designation text
HJRL_TEQB18 Calc teq,i according to B.18 1/0
HJRL_AGRSPC Aground spectral (according to GB/T 17247.2) 1/0
HJRL_2D_HM Use 2D-distance for calculation of hm (A.20) 1/0
HJRL_AGRBAR 0 = Aground not considered in case of single and multiple diffraction
1 = Aground not considered in case of multiple diffraction
2 = Use maximum of Aground and Abar
value

„Aircraft“ tab

Parameter 2ExplanationType
FLG_STRICTStrictly according to ... On/Off1/0
FLG_QParameter for Half-Value: 3 or 4value
FLG_INTEGRLmethod Integration of air corridor 0..3value
FLG_LK_55Use Levels Lk < 55dB On/Off1/0
FLG_REFTIMERef. Time Interval (s)value
FLG_DO_NATAzB75: Calc Number of Exceedances On/Off1/0
FLG_NAT_THRThreshold for NATs (dB)value
FLG_DO_STATAzB75: Maximum Level Statistics On/Off1/0
FLG_STAT_LOfrom Level (dB)value
FLG_STAT_HIto Level (dB)value
FLG_STAT_CWClass Width (dB)value
FLG_METRICmethod evaluation of maximum levels 0..2value
FLG_LMAX_MTAzB75: method evaluation of maximum levels 0..1value
FLG_LMAX_SDAzB75: Standard Deviation (dB) for Lmaxvalue
FLG_LMAX_COAzB75: Correction (dB) for Lmaxvalue
AZB_VBUFAzB75: Calculation acc. to VBUF On/Off1/0
FLG_US_HRCVAzB75: Use Height of Receiver On/Off1/0
FLG_NUM_CORNumber of Corridorsvalue
FLG_U_RASTF Use Raster Factor On/Off 1/0
FLG_RASTFAC Raster Factor value
FLG_U_MLDIF Use max. Diff of Level On/Off 1/0
FLG_MLDIFF max. Diff of Level (dB) value
FLG_U_MANGL Use max. Angle On/Off 1/0
FLG_MANGLE max. Angle (°) value
FLG_U_MLEN Use max. Length of Segment On/Off 1/0
FLG_MLENGTH max. Length of Segment (m) value
FLG_U_MLDEV Use max. Deviation of Curve On/Off 1/0
FLG_MDEVIAT max. Deviation of Curve (m) value
FLG_DENHRS Use Non-Standard Reference Time DEN On/Off 1/0
FLG_NAT_24H Scale NATs/Statistics down to 24h On/Off 1/0
FLG_AUT_GAM Automatic Calculation of Gamma On/Off 1/0
FLG_SCREEN with Screening On/Off 1/0
FLG_SAE5662 Propagation according to SAE AIR 5662 On/Off 1/0
FLG_DIN_STR DIN: Strictly acc. to DIN 45684 On/Off 1/0
FLG_DIN2010 DIN: Use Version 2011 On/Off 1/0
FLG_DINDENH DIN: Use Non-Standard Reference Time DEN On/Off 1/0
FLG_IMPRIAL INM/ECAC3: atmospheric data in imperial format On/Off 1/0
TEMP Temperature (°C), synchronized with the temperature specified on tab „Industry“ value
REL_HUMID relative Humidity (%), synchronized with the relative humidity specified on tab „Industry“ value
FLG_PRESS air pressure (hPa) value
FLG_VWIND headwind speed (m/s) value
FLG_DWIND INM/ECAC3: Wind Direction (°) value
FLG_MOD_NPD INM/ECAC3: Modify NPD Curves On/Off 1/0
FLG_BANKANG INM/ECAC3: Use Bank Angle On/Off 1/0
FLG_PERCEIV INM/ECAC3: Calc Perceived Levels On/Off 1/0
FLG_ICNTRY CNOSSOS: Calculation acc. to:
0: 2015/996 DE (BUF 2018)
1: 2021/1226 DE (BUF 2021)
value
FLG_BUF21_A Default-Auslastung BUF21 0/1
FLG_STAT_BEZ Evaluation of Max Levels: Name value
FLG_STAT_SUM Evaluation of Max Levels: Formula for Summation value
FLG_STAT_GES Evaluation of Max Levels: Formula for Total value

"Radar" tab

Parameter 2 Explanation Type
RAD_TZ 0 = No translation
1 = Use local time
2 = Use specific time zone
1...2
RAD_HREF_I 0 = Mean Sea Level (0m)
1 = Airport height
2 = User defined Height
1...2
RAD_HUSR User defined Height Value
RAD_H_PROF Use Heights from Profile 1/0
RAD_V_PROF Use Speeds from Profile 1/0
RAD_DO_RMAX Search Radius On/Off 1/0
RAD_RMAX Search Radius Value
RAD_QSIGMA Use Qsigma 1/0

„BPL“ tab

Parameter 2 Explanation Type
BPL_CALC Calculation of Optimizable Sources (type) 0 to 2
BPL_R_2D r is horizontal (2D) distance On/Off 1/0

Building Noise Map dialog

Parameter 2 Explanation Type
PT_TYPE type of calculation (via facade lengths, acc. to VBEB, acc. to CNOSSOS) 0..2
FACLEN_MIN minimal Length of Facade (m) value
FACLEN_MAX maximal Length of Facade (m) value
FAC_DIST Distance Rcvr - Facade (m) value
FAC_FREE Additional Free Space (m) value
AVG_METHOD Averaging Method 0..3
FOLL_TERR option „Height is following terrain“ On/Off 1/0
R_BEL_EAVE option „Lower Rcvr max. 20 cm below eave“ On/Off 1/0
DO_BNMAP Create Building Noise Map On/Off 1/0

Object-Scan

Parameter 2 Erläuterung Typ
QOTYP Object Type value
ACTION Action / Sum into value
ZOTYP Target Object Type value
REGEX Expression for ID value
ATTR0...3 Attribute value
MEMO0...3 Text Variable value
WSIZE Window Size value
RSTPRC Grid Point as Rectangle 1/0
SUMEX0...3 Formula for Summation value
GESEX0...3 Formula for Total value
VALID Formula for Validity of Grid Point value
PRESET Name of Preset:
EU02_EINW
EU02_EINW_FAC
EU02_EINW_NOF
EU02_EINW_FAC_GW
EU02_EINW_NOF_GW
EU02_RSTAREA
EU15_EINW
EU367
EU21_EINW_MEDIAN
EU21_RSTPKT_MAX_1
EU21_RSTPKT_MAX_2
EU21_RSTPKT_MIN_1
EU21_RSTPKT_MIN_2
DE21_EINW_MEDIAN
DE21_RSTPKT_MAX_1
DE21_RSTPKT_MAX_2
DE21_RSTPKT_MIN_1
DE21_RSTPKT_MIN_2
DE02_RSTAREA
VBEB
PT2BLD
LEG
value

Examples

ExampleComment
#(ObjAtt, CALCCONF, MAXERROR)exports/prints the maximum error as specified on the „General“ tab
#(ObjAtt, CALCCONF, MET_STABCD) exports/prints the stability class, for period Day (for Harmonoise, on the „Industry“ tab)
#(ObjAtt, CALCCONF, MET_VWINDD, 1) exports/prints the wind speed in m/s, for period Day (ibid)
#(ObjAtt, CALCCONF, MET_DWINDD, 1) exports/prints the wind direction in degrees, for period Day (ibid)